Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
  1. Currently, Syndeia supports updating of names and part structures from the SysML model to the PLM repository (and in reverse). Additional capabilities will be added in the future. In this exercise, we will continue with the models from the last section, adding an additional block, Payload, to the SysML model and using it as a part of the UAV. The resulting SysML model BDD looks like Figure 34the figure below.

    Figure 34 Modified UAV SysML model

     

  2. Refresh the Syndeia dashboard by right-clicking the Tutorial_2_04 package on the left side and choosing Refresh. It will appear similar to Figure 14as below.

    Figure 35 Syndeia dashboard, Connection Manager tab, after modifying SysML model, before updating PLM repository

  3. The corresponding Connection Browser tab appears as in Figure 36. For this screenshot, we (1) right-clicked on the Tutorial_2_04 package (top row) and selected Expand All, and (2) filtered the Connection column by clicking on the downward arrow icon in the column header, selecting (Custom…), and choosing "is not empty" criterion. This reduces the number of empty rows displayed.

    Figure 36 Syndeia dashboard, Connection Browser tab, after modifying SysML model, before updating PLM repository


  4. Use the Comparison Manager to display the current differences between the two models. Right-click on the Tutorial_2_04 package and choose Compare SysML & Target, as shown in Figure 37.

    Figure 37 Launching comparison

  5. The Comparison Result tab will be displayed, as in Figure 38. Note that the row are shown in red represents the new part property of UAV that has no corresponding element on the PLM side. Note that the new block, Payload, does not appear in the table, because it does not have an existing connection to a PLM object to compare against.

    Figure 38 Syndeia dashboard, Comparison result tab, after modifying SysML model, before updating PLM repository. 
     

  6. To update the PLM model from the revised SysML model, right-click on the Tutorial_2_04 package and select Sync SysML → Target. The results of this operation are shown for the Connection Manager (Figure 39), Connection Browser (Figure 40), and Comparison Result (Figure 41) tabs after syncing. It may be necessary to refresh each display. For the Comparison Result, you will need to perform the Comparison again to check that everything is in-sync, as shown in Figure 41.


Note that the version of the UAV part in Teamcenter has changed from A;1to B;1 (since 2 new part occurrences have been added), as shown in Figure 39. The connection between the UAV block in SysML and the UAV part in Teamcenter has been updated to point to this new revision (B;1), as shown in Figure 40.

The same updating result would have been achieved if we had synced the UAV block across connection C12 (Figure 36). By syncing across the Tutorial_2_04 package, we synced simultaneously across all 3 connections held by blocks in that package.

...

Close the Syndeia dashboard when the exercise is completed.
Image Removed

Figure 39 Connection Manager after syncing

Image Removed

Figure 40 Connection Browser after syncing

Image Removed

...


Image Added

Image Added

Image Added